12. Notes on electromagnetic compatibility
Recommended protective distances between portable and mobile
HF telecommunications equipment and the scales of type series 6702 and 6708
The 6702 and 6708 series scales are intended for use in the ELECTRONIC ENVIRONMENT specified below. The
customer or the user of the scales types 6702 and 6708 can help to avoid electromagnetic interference by main-
taining the minimum distance between portable and mobile RF telecommunication devices (transmitters) and the
scales types 6702 and 6708 - depending on the output line of the communication device, as specified below.
Nominal power of the
transmitter W
0,01
0,1
1
10
100
For transmitters whose rated power is not specified in the above table, the distance can be determined using the
equation associated with the respective column, where P is the rated power of the transmitter in watts (W) as
specified by the transmitter manufacturer.
NOTE 1:
An additional factor of 10/3 has been used to calculate the recommended separation distance of transmitters in
the frequency range of 80MHz to 2.5 GHz to reduce the likelihood that a mobile/portable communication device
inadvertently introduced into the patient area will cause interference.
NOTE 2:
These guidelines may not be applicable in all cases. The propagation of electromagnetic quantities is affected by
absorption and reflection from buildings, objects and people.
46
Protective distance depending on transmission frequency
150 kHz bis 80 MHz
d = 1,2 √P
0,12
0,38
1,20
3,79
4,0
m
80 MHz bis 800 MHz
d = 0,35 √P
0,04
0,11
0,35
1,11
3,50
800 MHz bis 2,5 GHz
d = 0,7 √P
0,07
0,22
0,70
2,21
7,00