36/49
Bosch Rexroth AG
Input/Output array
Serial output field
Tab. 5:
Bits
Outputs (status word)
1.00
End of Sequence (EOS)
1.01
Tip dress warning, electrode
1.02
Electrode warning
1.03
Max. electrode life
1.04
Timer ready
1.05
Weld fault
1.06
Without Monitoring
1.07
Firing enabled
1.08
Start tip dress request electrode
1.09
New Electrode
1.10
UI Regulation active
1.11
Acknowledge end of component
1.12
Tip Dress Cutter Warning
1.13
Tip Dress Cutter at End of Life
1.14
Pressure within tolerance
1.15
Spot selection data valid
2.00
Fault code 1
2.01
Fault code 2
2.02
Fault code 3
2.03
Fault code 4
2.04
Fault code 5
2.05
Fault code 6
2.06
Fault code 7
2.07
Fault code 8
2.08
Fault code 9
2.09
Fault code 10
2.10
Fault code 11
2.11
Fault code 12
2.12
Fault code 13
2.13
Fault code 14
2.14
Fault code 15
2.15
Fault code 16
3.00
Proportional valve programmed value 1
3.01
Proportional valve programmed value 2
3.02
Proportional valve programmed value 3
3.03
Proportional valve programmed value 4
3.04
Proportional valve programmed value 5
R911410786 | PSI6xCx.726