4.6 Technical data

General data
Mains supply:
Power consumption [P
]:
1
Rated motor capacity [P
2
Maximum pump head [H]:
Maximum pump flow [Q]:
Activation type [AT]:
Liquid temperature [t]:
Protection class:
Insulation class [Cl.]:
Speed [n]:
Maximum submersion:
Explosion protection:
Operating modes
Submerged [OT
]:
S
Emerged [OT
]:
E
Starts per hour
Recommended:
Maximum:
Free flow diameter
PRO V05-... :
PRO V06-... :
PRO V08-... :
Intake port
PRO...05-... :
PRO...06-... :
PRO...08-... :
Discharge port
PRO...05-... :
PRO...06-... :
PRO...08-... :
* When the motor is emerged, S1 operation is only
possible with the motor working at reduced perfor-
mance. Note the information about this in the type
code.
** To ensure the motor is cooled sufficiently, it must be
completely flooded for at least one minute before it is
switched on again!
The technical data shown apply to standard products in
the PRO series.
You will find the technical data of freely configu-
rable units in the PRO series in the enclosed data
sheet or your order confirmation.
36
see type plate
see type plate
]:
see type plate
see type plate
see type plate
see type plate
3 to 40 °C (37 to 104 °F)
IP 68
F (as an option: H)
see type plate
20 m (66 ft)
ATEX, FM
S1
S1*, S2 30 min, S3 50%**
20/h
50/h
50 mm (2 in)
65 mm (2.5 in)
80 mm (3 in)
50 Hz: DN 50
60 Hz: ANSI B16.1 125lbs 2
50 Hz: DN 65
60 Hz: ANSI B16.1 125lbs 2.5
50 Hz: DN 80
60 Hz: ANSI B16.1 125lbs 3.0
50 Hz: DN 50
60 Hz: ANSI B16.1 125lbs 2
50 Hz: DN 65/80
60 Hz: ANSI B16.1 125lbs 2.5/3
50 Hz: DN 80
60 Hz: ANSI B16.1 125lbs 3
4.7 Type code
Wilo-Rexa
Example:
PRO V06DA-110/EAD1X2-T0015-540-O
PRO
Series
Impeller shape
V
V = free-flow impeller
Discharge port size
05 = DN 50
06
06 = DN 65/80
08 = DN 80
Hydraulic version
P = for wet installation, intake side not drilled
D
D = intake side drilled according to DIN
N = intake side drilled according to North Ameri-
can Standard (ANSI)
Material type for hydraulics
A = standard type
B = corrosion protection 1
A
C = corrosion protection 2
D = abrasion protection 1
E = abrasion protection 2
X = special type
110
Hydraulics definition
Motor version
E
E = dry motor
R = performance-reduced dry motor
Material type for motor
A = standard type
B = corrosion protection 1
A
C = corrosion protection 2
D = abrasion protection 1
E = abrasion protection 2
X = special type
Seal version
D
D = 2 independent mechanical shaft seals
B = cartridge seal
1
IE efficiency class, e.g.: 1 = IE1
Explosion prevention
X = ATEX approval
X
F = FM approval
C = CSA approval
2
Number of poles
Mains supply version
T
M = 1~
T = 3~
0015
/10 = rated motor capacity P
Frequency
5
5 = 50 Hz
6 = 60 Hz
40
Code for rated voltage
Additional electrical equipment
O
O = with free cable end
P = with plug
2