Herunterladen Inhalt Inhalt Diese Seite drucken

Attribute 49, Warning Flag; Attribute 50, Operating Time - TR-Electronic C 58 Serie Benutzerhandbuch

Absolut encoder
Vorschau ausblenden Andere Handbücher für C 58 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Parameterization
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class

7.4.3.25 Attribute 49, Warning Flag

The Warning Flag displays that minimum one of the warn bits of "Attribute 47,
Warnings" is set to truth.
BOOL
Access
Get
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class

7.4.3.26 Attribute 50, Operating Time

Operating Time contains the counted operating time of the measuring system in
0.1 hours.
UDINT, read only
2
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class
 TR-Electronic GmbH 2013, All Rights Reserved
Page 140 of 175
0x23
Logical Type
Class #23
Value
Description
0
no warning occurred
1
warning occurred
0x23
Logical Type
Class #23
Byte 0
Byte 1
7
0
15
up to 2
2
0x23
Logical Type
Class #23
TR - ECE - BA - DGB - 0102 - 09
0x24
0x01
Instance #1
= Instance
0x24
0x01
Instance #1
= Instance
Operating Time
Byte 2
8
23
up to 2
2
up to 2
0x24
0x01
Instance #1
= Instance
0x30
0x30
Logical Type
Attr.-ID #48
=Attr.-ID
0x30
0x31
Logical Type
Attr.-ID #49
=Attr.-ID
Byte 3
16
31
24
2
up to 2
0x30
0x32
Logical Type
Attr.-ID #50
=Attr.-ID
Printed in the Federal Republic of Germany