0x38 - Measured
The "0x38 - Get inverter status extended" command is used for the extended querying of
value query "Get
the current inverter status. In the event of an error, the relevant status code is also output.
inverter status ex-
tended"
Query:
Start Length Device / Op-
Response:
Start Lengt
Explanation of "Inverter Status" byte:
Value
0x01
0x02
0x03
0x04
Please see the operating instructions for the relevant inverter for an explanation of status
codes.
Example of status code 301:
0x01
168
NOTE! In the event of a query, the inverter outputs every status code that is pres-
ent until the codes are no longer present. To prevent the inverter from outputting
an unnecessarily high number of status codes, it is recommended that a filter or
timer be implemented for queries to the inverter.
An example of circumstances under which the inverter may output an unneces-
sarily high number of status codes:
in the morning and the evening, when the solar radiation is very low and the in-
verter would issue the status codes "DC low" or "Power low" to every query.
In the event of uncertainty regarding the use of the 0x38 command, it is recom-
mended to use automatic display of status codes for inverters (0x07) - for more
detailed information, see chapter "Automatic Display of Status Codes", section
"0x07 - 'Set error sending' (Automatic Display of Status Codes - Inverters)".
tion
0x00
0x01
Device / Op-
h
tion
0x03
0x01
Meaning
Start-up
Operation
Manual standby
Failure
NOTE! The status code issued in the "Status Code" byte is only valid when the
inverter is issuing the value 0x04 (Failure) in the "Inverter Status" byte.
Status Code
0x2D
Number
Com-
Check-
mand
sum
0 - 99
0x38
Number
Com-
Inverter Status
mand
0 - 99
0x38
Explanation
The inverter is in the startup phase
The inverter is feeding power into the grid
The inverter has been set to standby mode by a user
action
The inverter is currently processing a status code
Status
Check-
Code
sum
MSB LSB