12 - WEEKLY CLEANING OPERATIONS

12.1 - BREWING UNIT AND JET CLEANING

Remove the filter-holder from the brewing unit.
Position the provided seal inside the filter, pour a spoonful of coffee-
machine detergent powder and fit the filter holder (22) into the
brewing unit to be cleaned. (21).
Operate the brewing unit by means of the unit control (17) and
interrupt delivery after approximately 4-5 seconds.
Alternatively operate and interrupt delivery for approximately one
minute, so as to allow removal of coffee and scale deposits.
Remove the seal and operate the delivery system several times to
rinse the unit.
Deliver a few servings of coffee so as to eliminate any unpleasant
taste from the jets and from the brewing unit.
After a long period of hot water stagnation within the conduits, let
water briefly flow vertically so as to remove any deposits.

12.2 - FILTER AND FILTER-HOLDER CLEANING

Frequently check the filter holes to remove any coffee deposits.
Prepare about a litre of boiling water with four teaspoons of coffee-
machine detergent in a suitable container, and immerse in this solu-
tion the filters and filter-holders for 20-30 minutes; then rinse thorou-
ghly under running water.
12.3 - DRAIN TRAY CLEANING
Remove the drain try grid (25) and pull out the drain tray (24) in
order to clean it from coffee powder residues.
12.4 - CASING CLEANING
Use a damp, non abrasive cloth, without alcohol or solvents, to avoid
damaging the sides, the base and any painted parts.

13 - REPLACING THE GROUP GASKET

A. round metal block
B. sprayer
C. jet
D. gasket
E. jet fixing screw
F. filter
G. filter-holder.
Downloaded from
www.Manualslib.com
manuals search engine
If, during delivery, the coffee drips out of the edges of the filter-holder
(G), this may be caused by the obstruction of the filter-holder delive-
ry hole, in which case the hole needs to be cleaned; if the problem
persists or, if when fitting the filter-holder into the brewing unit it
significantly moves beyond the unit centre, the group gasket needs
replacing (D).
In order to replace it, unscrew the jet fastening screw (E), remove the
jet (C) and the sprayer (B), and then use a screwdriver as a lever to
remove the round metal block (A) and subsequently the gasket (D).
After having removed the gasket, thoroughly clean the seat before
placing the new gasket, after which reinstall the component by fol-
lowing the above listed steps in reverse order.
14 - BOILER WATER REPLACEMENT
It is essential to replace the water contained in the boiler every
15-20 days, in order to eliminate the iron bacteria and the build-up
of various residues due to water stagnation.
Turn off the main switch (3), remove the drain basin grid (25) and
pull out the lower drain basin (24).
Open the drain tap placed under the level glass (with the boiler
under pressure) and let the water flow out of the boiler completely.
Close the tap again and repeat the start-up procedures by following