Read Request during Parameter Write Operation:
Function Number = 0x5F (Write Request)
Slot Number
Index = 47 (Defined for
the read/write of parameters)
Length = Length in Bytes of the
DPV1 Data of the Read Response (If Error)
= 4 + n * 4
Read Response during Parameter
Write Operation:
Read Request
Function Num = 0x5F
Successful
(Mirrored)
Slot Number (Mirrored)
Index (Mirrored)
Length (Mirrored)
Request Reference
(Request Allocation)
Request ID = 0x02
(Parameter Write)
Node ID = 127 = 0x7F
Number of Par. = Quantity of
Parameters
Instruction Manual/Betriebsanleitung BG 45 PB, Version: 1.0 en_de
© 2011 Dunkermotoren GmbH; D-79848 Bonndorf; Germany
Read Request bei Parameter schreiben:
Function Num = 0x5F (Read Request)
Slot Number
Index = 47 (definiert für Parameter
lesen und schreiben)
Length = maximale Länge [Byte] der DPV1
Daten der Read Response (im Fehlerfall) =
4 + n * 4
Read Response bei Parameter
schreiben:
Read Request
Function Num = 0x5F
In Ordnung
(gespiegelt)
Slot Number (gespiegelt)
Index (gespiegelt)
Length (gespiegelt)
Request Reference
(Zuordnung der Aufträge)
Request ID = 0x02
(Parameter schreiben)
Node ID = 127 = 0x7F
Anzahl n der zu
schreibenden Parameter