1 Explanation of the motorcodes

In consideration of the varoius power supply systems BITZER offers motors with different operating voltages and
frequencies for all compressors. In the following tables the available operating voltages for the specific com-
pressors are listed. To identify the operating voltages and the motor connection, BITZER adds the motor code to
the compressor name.
Fig. 1: Explanation of the motor code for reciprocating compressors
Example
For the motor code 40S the following table shows the different motor connections for the respective operating
voltages and frequencies:
• 220-240 V / 3 / 50 Hz / ∆
• 380-420 V / 3 / 50 Hz / Y
• 440-480 V / 3 / 60 Hz / Y
Voltage range (V) Nominal voltage
50 Hz
220-240
380-420
KT-410-5 // PDF Download
4 K T E U - 1 0 L K - 4 0 S U
Compressor type
Motor size
Line start permanent magnet
motor (LSPM)
Indication for nominal voltage
400 V / 50 Hz
Motor size / Motor type
S = Star wiring
D = Delta wiring
P = Part winding
N = Dual voltage
E = Single-phase
U = UL approval
Motor code
(V)
230
40S
400
40S
Motor connec-
Nominal voltage
tion
Y
Voltage range (V)
(V)
60 Hz
-
-
460
440-480