Technical Data
Designation
Order number 6SE70...
Rated voltage
Rated frequency
Rated current
DC link voltage
Rated output
Aux. power supply
Pulse frequency
Load class II acc. to EN60146-1-1:
Base load current
Overload current
Cycle time
Overload duration
Losses, cooling, power factor
Power factor
Efficiency η
Dissipated losses
Cooling air required
Sound pressure level, dimensions, weights
Sound pressure level [dB(A)]
Type of construction
Dimensions
Width
Height
Depth
Weight approx.
11-6
Downloaded from
www.Manualslib.com
23-4EC 1
[V]
Input
Output
[Hz]
Input
Output
[A]
Input
37.4
Output
34.0
[V]
[kVA] 22.4...27.1 24.7...29.9 30.9...37.4 38.8...47.0 47.4...57.4
[V]
[kHz]
Line cosϕ1N
> 0.98
Converter cosϕU
< 0.92 ind.
Pulse frequency 5 kHz
0.98
[kW]
Pulse frequency 5 kHz
0.59
[m³/s]
0.028
[mm]
180
600
350
[kg]
= 5 corresponds to MASTERDRIVES Motion Control
= 7 corresponds to MASTERDRIVES Motion Control Performance 2
Table 11-4
manuals search engine
Value
23-8ED 1
24-7ED 1
3 AC 380 to 480 (-15 % / +10 %)
3 AC 0 up to rated input voltage x 0.86
50/60 ± 6 %
0 ... 400
41.3
51.7
37.5
47.0
510 ... 650
DC 24 (20 -30) (2.0 A without options; more with options)
5.0 - 10.0
0.91 x rated output current
1.6 x rated output current
300 s
> 0.98
> 0.98
< 0.92 ind.
< 0.92 ind.
0.97
0.98
0.70
0.87
0.054
0.054
60
65
65
C
D
D
270
270
600
600
350
350
21
32
32
Technical data
Operating Instructions
26-0ED 1
27-2ED 1
64.9
79.2
59.0
72.0
30 s
> 0.98
> 0.98
< 0.92 ind.
< 0.92 ind.
0.98
0.98
1.02
1.27
0.054
0.054
65
65
D
D
270
270
600
600
350
350
32
32
6SE7087-6JD50
Siemens AG
SIMOVERT MASTERDRIVES
08.2009