1.5

Plates and symbols

1.5.1

Safety / warning symbols, note symbols

DANGER – Serious damage to health / risk to
life
This symbol in conjunction with the signal word
"DANGER" indicates an imminent danger. Failure
to observe this safety information will result in
death or severe injury.
DANGER – Serious damage to health / risk to
life
This symbol in conjunction with the signal word
"DANGER" indicates an imminent electrical
hazard. Failure to observe this safety information
will result in death or severe injury.
WARNING – Bodily injury
This symbol in conjunction with the signal word
"WARNING" indicates a potentially dangerous
situation. Failure to observe this safety
information may result in death or severe injury.
WARNING – Bodily injury
This symbol in conjunction with the signal word
"WARNING" indicates a potential electrical
hazard. Failure to observe this safety information
may result in death or severe injury.
CAUTION – Minor injuries
This symbol in conjunction with the signal word
"CAUTION" indicates a potentially dangerous
situation. Failure to observe this safety
information may result in minor or moderate
injury. The symbol may also be used for property
damage warnings.
NOTICE – Property damage
This symbol indicates a potentially damaging
situation.
Failure to observe this safety information may
result in damage to or destruction of the product
and / or other system components.
IMPORTANT (NOTE)
This symbol indicates operator tips, particularly
useful information, or important information about
the product or its further uses. The signal word
"IMPORTANT (NOTE)" does not indicate a
dangerous or harmful situation.
1.5.2

Name plate

1
CoriolisMaster
2
Model no.: FCB350Y0Y0015E1D2A1C2D1A1A
3
Order no.: 000351160 / X001
4
U/f nom:
100...230 V 50/60 Hz
5
Size:
DN 20 / IP 67
6
Fitting:
DN 25 / PN 40
7
Material:
1.4571
8
K:
40.375 Cal.: V: +/-0.4 % D: +/- 5 g/l
Qmax DN: 100 kg/min
9
Tmed: -50 °C...+180 °C Tamb: -20 °C....+60 °C
10
ABB Automation Products GmbH
37079 Göttingen – Germany
11
Fig. 1:
Name plate for integral mount design flowmeter sensor
1 Full designation | 2 Order code | 3 Order number |
4 Power supply | 5 Nominal diameter / Degree of protection |
6 Process connection / Pressure rating | 7 Meter tube material |
8 Calibration factor | 9 Maximum flow rate |
10 Medium temperature range | 11 Manufacturer |
12 Year of construction (month / year) |
13 Ambient temperature range | 14 Communication |
15 Calibration accuracy | 16 PED mark |
17 Maximum power consumption | 18 CE mark
1.6

Transport safety instructions

Observe the following instructions:
— Do not expose the device to moisture during transport.
Pack the device accordingly.
— Pack the device so that it is protected against vibrations
during transport, e.g., by using air-cushioned packaging.
— Depending on the device, the center of gravity may not be
in the center of the equipment.
1.7

Installation safety instructions

Prior to installation, check the devices for possible damage
that may have occurred as a result of improper transport.
Details of any damage that has occurred in transit must be
recorded on the transport documents. All claims for damages
must be submitted to the shipper without delay and before
installation.
— The flow direction must correspond to the direction
indicated on the meter (if labeled).
— The maximum torque must not be exceeded for all flange
connections.
— The meters must be installed without mechanical tension
(torsion, bending).
— Install flange devices with coplanar counter flanges.
— Equipment must only be installed for the intended operating
conditions and with suitable gaskets.
— Flange bolts and nuts must be secured to provide
protection against pipeline vibrations.
CoriolisMaster FCB330, FCB350 | CI/FCB300-X1 EN - 5
Pmax: 25VA
PED.: xxx
Var.: HART
Year 02/2012
18
17
16
15
14
13
12
G10308