TP 4000 CEL / TP
No welding current
5000 CEL power
Mains switch is ON, overtemperature indicator is lit up
source
Cause:
Remedy:
98
Phase failure
Check the mains fuse, the mains lead and the mains plug
Mains undervoltage: The mains voltage has fallen below the tolerance range
(+/- 15%)
Check the mains voltage
Mains overvoltage: The mains voltage has exceeded the tolerance range (+/
- 15%)
Check the mains voltage
The earth current watchdog has triggered the safety cut-out of the power
source.
Switch off the power source, wait for 10 seconds and then switch it on again.
If you have tried this several times and the error keeps recurring, contact Af-
ter-Sales Service.
The earth current watchdog has triggered the safety cut-out of the power
source.
Switch off the power source, wait for 10 seconds and then switch it on again.
If you have tried this several times and the error keeps occurring, contact Af-
ter-Sales Service.
r alignment: there is no contact with the workpiece
Switch off the power source, wait 10 seconds and then reconnect the ground-
ing cable; establish a tight connection between the electrode holder and the
workpiece
r alignment: procedure has been interrupted by repeated pressing of the Set-
up / Store button (7)
Establish a tight connection between the electrode holder or the clamping
body for the tungsten electrode and the workpiece – press the Setup / Store
(7) button once
r alignment: poor contact between electrode holder or clamping body for tung-
sten electrode and workpiece
Clean the contact point, clamp the electrode holder or the clamping body for
tungsten electrode securely or press it against the workpiece, check the
grounding (earthing) connection
The fan in the power source is faulty
Change fan