Herunterladen Inhalt Inhalt Diese Seite drucken

Adjustment Of Wind Direction - Toshiba SUPER MMU-AP0091H Betriebsanleitung

1/2/4-way air discharge cassette type/ outdoor unit
Vorschau ausblenden Andere Handbücher für SUPER MMU-AP0091H:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 52
[In Cooling operation]
• The operation starts after approx. 1 minute.
[In Heating operation]
• In heating operation, the fan operation may continue for approx. 30 seconds after the air conditioner has
stopped.
• The indoor fan continues preheat operation for 3 to 5 minutes under stop condition, and then blows out
the hot air.
(
display on the remote controller display part goes on.)
• When temperature of the room has reached the setup temperature and the outdoor unit stops, the air
speed becomes super low and the air volume extremely is lessened.
• In the defrost mode, the fan stops so that cool air is not discharged and PRE-DEF
[In Automatic operation]
• Using the difference between the setup temperature and the room temperature, the heating or cooling
operation is automatically performed.

ADJUSTMENT OF WIND DIRECTION

To increase the cooling or heating effect, be sure to use the discharge flap in the different
directions in cooling or heating operation.
As the characteristics of the air, the cold air accumulates at lower side and hot air at upper side, respectively.
Set the discharge flap horizontally in cooling operation.
If cooling operation is performed with downward discharge, the surface of the discharge port or louver will
be wet with dew, and dewdrop may fall down.
• If heating operation is performed with horizontal discharge, unevenness of temperature may increase in
the room.
4-way Air Discharge Cassette Type
• While the air conditioner stops, the discharge flap automatically directs downward.
• While the air conditioner is in ready status for heating,
the discharge flap directs upward.
The swinging operation starts after heating ready status
has been cleared, but "SWING
remote controller even if the status is ready to heating.
[In Cooling operation]
Use the discharge flap with horizontal set point.
[In Heating operation]
Use the discharge flap with downward set point.
REQUIREMENT
CAUTION
REQUIREMENT
" is displayed on the
9
is displayed.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis