Timer operation
• Three timer modes are available: (Setting of up to 168 hours is enabled.)
Off timer
: The unit stops when the set time is reached.
Repeat Off timer : The unit stops daily when the set time is reached.
On timer
: The unit starts when the set time is reached.
1
3
◆ Set
1
Push
button.
The timer mode changes with every push of the
button.
Off
Off
(Off timer)
(Repeat Off timer)
(On timer)
No display
•
and timer display fl ashes.
2
Push
to select "set time".
• With every push of
button, the set time
increases by 0.5 hr (30 minutes).
To set a time more than 24 hours for timer
operation, timer can be set in increments of 1 hr.
The maximum set time is 168 hr (7 days). The
remote control displays the set time with time
(between 0.5 and 23.5 hours) (*
1
) or number of
days and time (24 hours or more) (*
2
) as shown
below.
• With every push of
button, the set time
decreases by 0.5 hr (30 minutes) (0.5 - 23.5
hours) or 1 hr (24 - 168 hours).
Example of remote control display
• 23.5 hours (*
1
)
19-EN
2
4
• 34 hours (*
)
2
Number of days
Time
shows 1 day (24 hours).
On
shows 10 hours. (Total 34 hours)
3
Push
button.
•
icon disappears and time display goes on,
and
or
icon fl ashes.
(When On timer is activated, time and On timer
are icons and other icons disappear.)
4
Cancel timer operation.
Push
button.
Timer icon disappears.
NOTE
• When the operation stops after the timer reached
the preset time, the Repeat Off timer resumes the
operation by pushing
button and stops the
operation after the time of the timer has reached the
set time.
• When
is pushed while the Off timer function of
the air conditioner is active, the indication of the timer
function disappears and then appears again after
about 5 seconds.
This is due to normal processing of the remote
controller.
6
Adjustment of wind direction
For best cooling and heating performance, adjust the
louvers (adjustment plates of up / down wind direction)
appropriately. Cold air descends and warm air rises, so
to heat a room tilt the louvers downward, and to cool a
room tilt them horizontally.
CAUTION
Direct the louvers horizontally for cooling.
If the louvers stay pointed downward during cooling,
condensation may form on the discharge port and /
then drops from the louvers.
• When operation is stopped, the horizontal louver
(plate for adjusting the vertical air fl ow) automatically
closes.
• In heating preparation mode, the horizontal louver
(plate for adjusting the vertical air fl ow) points
upward. The louver starts swinging when the heating
preparation mode has fi nished, but the swing
indicator appears on the remote controller even in
heating preparation mode.
As characteristics of air, cold air
accumulates lower area and warm
air accumulates upper area.
– 10 –
1
Unit select
button
◆ How to set up the wind direction
1
Push
during operation.
The wind direction changes for every push of the
button.
In Heat operation
Direct the louver (adjustment plate of up / down wind
direction) downward. If directing at horizontally, hot air
may not come to the foot.
Initial setup
In Cool / Dry operation
Direct the louver (adjustment plate of up / down wind
direction) horizontally. If directing it downward, the dew
may form on the surface of the air discharge port and
may drop down.
Initial setup
In Fan operation
Select a desired wind direction.
Initial setup
20-EN