13.4 „Left-Right" Positioning Mode
The "Left-Right" positioning mode is a versatile
configurable operating mode that makes possible for
the user to drive back and forth between two different
positions in a simple manner.
With the „Load to motor" button, the user has the
possiblity of loading mode-specific parameter adjust-
ments to the motor with the aid of the parameterising
interface.
Loading the currently selected
project will reset all motor's settings.
The motor will be freely rotatable.
NOTICE
The controlling of the positionings takes place via the
digital inputs that are coded as follows:
IN 0
Function
0
Limit switch OFF
1
Limit switch ON
IN 1
IN 2
IN 3
0
0
0
1
0
0
0
1
0
0
0
1
Instruction Manual/Betriebsanleitung BG 65 PI, Version: 1.4 en_de
© 2010 Dunkermotoren GmbH; D-79848 Bonndorf; Germany
Function
Clear error and
STOP
Begin homing
Position 1
Position 2
13.4 Positioniermodus „Left-Right"
Bei dem Positioniermodus „Left-Right" handelt es sich
um einen vielfältig konfigurierbarer Betriebsmodus
der es dem Anwender auf einfache Weise ermöglicht
zwischen zwei Positionen hin und her zu fahren.
Mit der „Load to motor"-Schaltfläche hat der Anwender
die Möglichkeit, modispezifische Parametereinstel-
lungen auf den Motor zu laden.
Durch die Übertragung des aktuellen
Projektes auf den Motor werden alle
bisherigen Einstellungen gelöscht.
Der Motor ist nun frei bewegbar.
HINWEIS
Die Ansteuerung der Positionierungen erfolgt hierbei
über digitale Eingänge, die wie folgt aufgeschlüsselt
sind:
IN 0
Funktion
0
Limit Schalter AUS
1
Limit Schalter EIN
IN 1
IN 2
IN 3
0
0
0
1
0
0
0
1
0
0
0
1
Funktion
Error beseitigen und
STOP
Homing beginnen
Position 1
Position 2
55