Page GB-30
Installation and connection
Power supply – notes for the
electrician
WARNING
Electric shock / fi re hazard!
The improper installation of electrical
connections may cause electric shock
which can lead to serious injury or even
death.
Only an authorised electri-
■
cian who is approved by the
local power supply compa-
ny, for example, our technician, may
connect and disconnect the cooker
set from the mains supply (see "Our
service" on page GB-35). Only then will
you benefi t from our warranty and a
suffi cient level of safety.
Since all poles of the appliance can-
■
not be disconnected from the mains
via an accessible disconnecting de-
vice, an all-pole disconnecting device
in accordance with overvoltage cat-
egory III must be connected within
the house installation with at least 3
mm contact clearance; this includes
fuses, miniature circuit breakers and
protective devices.
Connection conditions
The oven is designed for the following alter-
nating voltages:
– 220–240 V ~, 50/60 Hz, 50 A
– 380–415 V 2N~, 50/60 Hz, 25 A
– 380–415 V 3N~, 50/60 Hz, 16 A
– A separate power supply is required.
– The power cord used must comply with
the requirements of DIN EN 60335-1 (e.g.
H05RR-F model).
– Depending on the type of connection, the
conductor cross-section must be selected
and the contact bridges inserted or re-
moved (see following figures).
– When connecting the appliance, VDE re-
quirements and the 'Technical connection
requirements' must be observed.
Contact protection must be guaranteed.