Primary:
Mains voltage
Mains fuse
Consumption max.
Efficiency
Secondary:
Current range DC
Duty cycle 100%
Duty cycle 60%
Duty cycle 30%
Max. open circuit voltage DC
Max. arc voltage by max. load
Electrode diameter
1
Protection class
2
Application class
Insulation class
Standards
Permissible ambient temperature:
Storage
Operation
Extension cable
Dimension and weight:
Dim. HxWxL
Weight
Circuit diagram
F
N
PE
PRIMARY
1
The machine is designed for outdoor applications as it meets the demands of protection class IP23.
2
S
This machine meets the demands made for machines which are to operate in environments with an increased
hazard of electric shocks.
TECHNICAL DATA
-
+
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
POT
LED
LED
FRONT PANEL
1x230 V ± 10%
16 A
7.6 kVA
0.85
7 - 150 A
100 A / 24 V
120 A / 24.8 V
150 A / 26 V
90 V
26 V
1.6 – 3.25 mm
IP 23
S
B
EN60974-1
EN50199
-20°C - +60°C
-20°C - +40°C
min. 1.5 mm²
max. 30 m
27x18x25 cm
4.6 kg
1
2
3
4
5
6
7
1 2
1 2
8
9
10
21
1
2
3
4
5
6
7
8
9
10
SECONDARY