Description of unit
3.5 Technical data ProSpray 21
Voltage:
Max. current consumption:
Fuses:
Unit connecting line:
Acceptance capacity:
Max. operating pressure:
Volume flow at 120 bar
(12 MPa) with water:
Max. tip size:
Max. temperature of the
coating material:
Max. viscosity:
Weight:
Special high-pressure hose: DN 6 mm, 15 m connecting
Dimensions (L x W x H):
Max. sound pressure level:
* Place of measuring: 1 m in distance from the unit and 1.6
m above the floor, 120 bar (12 MPa) operating pressure,
reverberant floor.
3.6 Transportation in vehicle
Secure the unit with a suitable fastening.
30
230 V AC, 50 Hz
4.5 A
16 A time-lag
3 x 1.5 mm
2
– 6 m
1035 Watts
230 bar (23 MPa)
1.75 l/min
0.021 inch – 0.53 mm
43°C
20.000 mPa·s
15.5 kg
thread M 16 x 1.5
480 x 345 x 405 mm
80 dB (A) *
g
4. Starting operation
4.1 High-pressure hose, spray gun and
separating oil
1. Screw the manometer combination (2) at the coating
material outlet (Fig. 2, Item 1).
2. Screw the transition socket (3) to the manometer
combination.
3. Screw the high-pressure hose (4) to the manometer
combination.
4. Screw the spray gun (5) with the selected tip onto the
high-pressure hose.
5. Tighten the union nuts at the high-pressure hoses
firmly so that coating material does not leak.
1
2
3
4
Starting operation
5
ProSpray 21