c) Discharging Batteries ("DISCHARGE")
• After you have selected the "Pb" program in the main menu with the button "TYPE/
STOP" and confirmed this with the button "ENTER/START", you can select the discharge
function using the button "+" or "-":
Pb DISCHARGE
Pb DISCHARGE
Pb DISCHARGE
Pb DISCHARGE
Pb DISCHARGE
0.1A
0.1A
0.1A
0.1A
0.1A
The value on the left in the second line shows the discharge current, the value on the
right shows the voltage or number of cells of the battery (in this example, a 6-cell lead
battery, 6 x 2.0 V = 12.0 V).
• If the values need to be changed, press the "ENTER/START" button. The discharge
current flashes. Change the discharge current using the keys "+" and "-", confirm the
value using the "ENTER/START" key.
• The voltage/cell number then begins to flash. Change this using the buttons "+" and "-".
You should be aware while doing this that the voltage only changes with the number of
cells (e.g. one cell = 2.0 V, two cells 4.0 V etc.) Confirm the setting by pressing the
"ENTER/START" button.
For safety reasons, the charger sets the final discharge voltage automatically.
• To begin the discharge process, keep the "ENTER/START" button pressed (approx.
3 seconds).
• If the settings are wrong, or if the charger detects a problem, an audio signal is emitted
and the appropriate information is shown on the display.
You can stop the warning signal by pressing the "TYPE/STOP" button. You then return
to the previous configuration menu.
• If you press the button "ENTER/START" during the discharge process, the discharge
current can be changed (see above).
• Once the discharge process has been completed, an audio signal is emitted.
If you wish to terminate the discharging process beforehand, press the
"TYPE/STOP" button.
86
12.0V(6P)
12.0V(6P)
12.0V(6P)
12.0V(6P)
12.0V(6P)