Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning; Troubleshooting; Safety Instructions; Causes Of Malfunctions And Their Rectification - Heiniger Xplorer Originalbetriebsanleitung

Vieh- und pferdeschermaschine
Vorschau ausblenden Andere Handbücher für Xplorer:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
NOTICE
Possible damage to the clipper!
Insufficient oiling of the clipping head will lead to warming and will shorten the life of the
clippers and its blades.
Oil the clipping blades adequately during the clipping session, at least once every 15
minutes, so that they do not run dry.
Only use the special oil supplied or a paraffin oil conforming to the ISO VG 15 specifi-
cation.
NOTE
The supplied oil is free of poisonous substances and will not cause irritations on either
skin or mucous membranes. After 21 days, it will have degraded to about 20% (CEL-
L-33-T-82).
• Oil the blades prior to, during and after every use.
• Oil the blades at the latest when the blades leave streaks or slow down.
• Apply several drops of oil on the front and on the sides of the clipping blades (see Fig.
15).
• Immediately replace damaged or notched blades in order to avoid injuries.
7.10

Cleaning

NOTICE
Improper cleaning.
Risk of damaging the clipper.
Use only a dry cloth and the brush provided to clean the clipper.
Never use compressed air for cleaning.
Housing of the clipper
Clean the housing of the clipper with a dry cloth.
Clipping blade, clipping head and charger
Disconnect the charger from the power supply.
Use the brush supplied to clean the clipping blades, clipping head and charger.
Lubricate the clipping blades as described in chapter 7.9.
Remove any hair from the charging bay.
Clean the terminals with a dry cloth if necessary.
40

8 Troubleshooting

8.1 Safety instructions

Mortal danger from electrical current!
Mortal danger can result from contact with current-carrying conductors or components!
During the warranty period the device must be opened only by personnal authorised by the
manufacturer, else the warranty will be void.

8.2 Causes of malfunctions and their rectification

Malfunction
Upper blades moving
too little.
Upper blade does not
move.
Adjusting knob is jam-
med.
Leaf springs in the
head mount are too
loose.
Play between swi-
velling lever and leaf
spring.
Swivelling lever is dif-
ficult to move up and
down.
Cattle and Horse Clipper
Cattle and Horse Clipper
DANGER
Switch the equipment off before troubleshooting the problem.
Repairs to electrical devices must only be carried out by the factory service depart-
ment or specialists who have been trained by the manufacturer.
Possible cause
Leaf springs have broken.
Square end of eccentric shaft
or eccentric shaft worn (insuf-
ficient lubrication).
Defective gear.
Thread is dirty or rusty.
Pressure spring is jammed.
Comb plate screws are loose.
Leaf springs and/or cylinder
head screws are worn.
Centring sleeve lost.
Corrective measure
Notify customer service.
Notify customer service.
Notify customer service.
Tighten the comb plate screws.
Notify customer service.
Notify customer service.