Instructions for Stainless Steel Vertical Column Installation
GB
GB
Assembling the Vertical Column
3.1. Column with one Behnke door intercom
Height 1.75 m for pedestrians (for example)
1 ▸ Fix the door intercom or the module in
question to the column. To do so, please use
the screws provided in the box. Use a clamping
plate to fix the door intercom's lower end.
2 ▸ Then fix the cover panel marked "start
module" so that the straight cut edge points
towards the end of the column. The chamfered
edge points towards the Behnke door intercom
device or towards the module frame. Use a
second clamping plate to fix the lower edge of
the cover panel.
3 ▸ Use the cover panel marked "closing
module" to close the remainder of the column.
In case the cover panel is too long, please
shorten it accordingly. Please note that the
distance to the column's base must not be
greater than 5 mm.
4 ▸ When fixing the "closing module", please
make sure that the two drilled holes point up.
The lower edge will be fixed to the column's
base with an angle piece (cf. page 34).
41
Pedestrians
2
2
15 V power supply
unit 20-9585
e.g..for camera and
basic electronics
(for additional infor-
coax cable for camera / video feed
mation concerning
or screened and twisted two wire
the additional pow-
cable (100m max.)
er supply, please
confer to the basic
electronics manual
or the manual for
the installed devic-
es, respectively.)
Please provide the corresponding
network cabling for SIP intercom stations.
Directly screw the intercom
station into the column
Speaker
21-1100
Professional camera (illumi-
nated) 21-2903
Call button, label 21-2011
Microphone 21-3100
Clamping plate to fix the
intercom station and the
first cover plate or additional
intercom stations.
Cover panels set 1
21-5334
Clamping plate
Telephone connection
www.behnke-online.de