Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

[Seite 34]
MAX LimitAirSpd
Max. Airspeed
Min. AirSpeed
SpeedRegVal-P
SpeedRegVal-I
SpeedRegVal-D
MinRPM SpdCtrl
Adjusting the glowplug voltage:
This is the procedure for adjusting the glowplug voltage:
1. Select the "GlowPlug Power" parameter in the LIMITS menu (leaf through using the +/- buttons).
2. Press and hold the "Change Value/Item" button -> the glowplug is switched on, and the edit arrow
appears before the voltage value on the screen. You can now adjust the glowplug voltage using the +/-
buttons (all the while holding the "Change Value/Item" button pressed in). Adjust the glowplug voltage
until the pulled-out filament glows bright red.
3. As soon as you release the "Change Value/Item" button again, the new value is stored, and the glowplug
is switched off.

Smoker valve

The ECU can directly control a valve for blowing smoke fluid / diesel fuel into the exhaust efflux (-> smoke
generation).
The Smoker valve can be the same type used for the fuel shut-off valve (Order No. 61106-00).
The function of the Smoker valve can be adjusted in the Limits menu (parameter: "SmokerValve Ctrl").
The possible options for the "SmokerValve Ctrl" parameter (-> LIMITS menu) are:
Option
DISABLED
Open if AuxSw=0
(*)
Open if AuxSw=2
(*)
(*) The function of the Smoker valve can be tested when the turbine is not running:
1. Set the throttle stick and trim to idle or OFF (otherwise there is a danger that the fuel pump will start
running during the subsequent test process!). For safety's sake disconnect the fuel line to the turbine.
2. Press and hold the "Manual" button (-> yellow LED flashes). The valve can now be operated using the
AUX switch (3-position switch on transmitter).
See page 37
See page 37
See page 37
See page 37
See page 37
See page 37
See page 37
Description
Smoker valve not used.
The valve is always closed!
Smoker valve is opened when the AUX switch (3-position switch) is moved to the
back ("OFF") position when the turbine is running.
If you wish to be able to use this function, the AUX switch must be active, i.e. the
"AUX-channel func" parameter (see below) must not be set to "NOT USED".
Smoker valve is opened when the AUX switch (3-position switch) is moved to the
forward ("ON") position when the turbine is running.
If you wish to be able to use this function, the AUX switch must be active, i.e. the
"AUX-channel func" parameter (see below) must not be set to "NOT USED".
32