Instructions for the installer, maintenance
6.4 Malfunctions of the Refrigeration System
Problem
Refrigeration system does not
work.
The compressor works but the
temperature is not ideal.
Evaporator covered with ice.
The compressor works, but it heats
up and does not cool down.
technician, and end user
Possible Causes
The machine is not powered up.
The door switch is not activated.
The control unit is defective or
there are connection problems
The control unit is defective
Dirty condenser.
The vending machine is positioned
to close to the wall
The condenser fan does not work.
The evaporator fan does not work.
Temperature regulation is not
exact.
Insufficient refrigeration in the
system.
Evaporator fan does not work.
The cooling compartment is badly
sealed.
Check the ends of the capillary
hose
Page 56 of 60
Recommended Solutions
Check the energy source. Check the
power cord connections and any fuses
present.
Check the door closure and the switch
operation.
Check the connections of wiring and the
control unit
Replace the control unit
Check the fins of the condenser to see if
they are dirty or blocked.
Clean them with a stiff brush.
Make sure that the space between the
back grille and the wall is at least 10 cm
wide.
Check to see if it is blocked.
Check the circuit. Replace the motor.
Check the circuit. Replace the motor
and check the fan to make sure it isn't
blocked. Check the relay board and the
connections to the switchboard.
Set the desired temperature (ref.
Programming manual).
Replace the refrigeration system.
Check the circuit. Replace the motor
and check the fan to make sure it isn't
blocked.
Check the relay board, check the
connections to the board.
Change the seal and/or adjust the
internal door closure.
Make sure that the product door closes
correctly after delivering the product.
If after 5 minutes of operation, no ice
forms, there are leaks.
Replace the refrigeration system.
© SandenVendo Europe SpA