5.8
The UV effect of the lamps and thus the tanning effect decreases over the
course of time. Therefore, the replacement intervals specified in the
maintenance plan must be adhered to.
UV filters are utilised in order to control the UV radiation, e .g. the filter panels
on the facial tanner. However, the filter effect decreases over the course of
time. Therefore, the replacement intervals specified in the maintenance plan
must be adhered to.
5.8.1
Replace faulty UV low pressure lamps immediately.
Always replace the entire set of lamps after the specified operating time.
Turn 90° and carefully remove from the socket.
03108 / 0
UV low pressure lamps possess a reflector which directs the light
outwards. The lamps must be mounted in such a way that the rear side of
the reflector is located on the device side.
Push the pins vertically into the socket from above.