Verfügbare Sprachen

Faults
Error
Error
message
message
display [5]
display [9]
ERR
CFG
ERR
PRG
ERR
TFS
ERR
HAR
ERR
t°C
ERR
H2O
ERR
SLC
ERR
FCC
In the event of the error messages above, contact REHM's customer service departments.

7.3 Error messages

Error code
display [21]
0000 to 0004 Faulty machine configuration
0100 to 0102 Faulty welding program
02
00 Faulty memory
03
00 Alarm OVER VOLTAGE. Welding impossible
03
01 Alarm UNDER VOLTAGE. Welding impossible
03
02 Alarm UNDER & OVER VOLTAGE. Welding impossible
03
03 Alarm PRIMARY OVERCURRENT. Welding impossible
04
00 Alarm Thermostat. Fan wheels operating. Welding
impossible
05
00 Water cooling unit faulty
06
00 Feed unit faulty
06
01 Controller not plugged in
06
02 Error on external accessory
06
03 Error on external accessory
0700 to 0701 Incorrect software program
8

Service and maintenance

8.1

Safety notes

Warning!
Repair and maintenance work may only be carried out by personnel who
have been trained by REHM. Contact your REHM representative. When
replacing parts, only use original REHM parts.
If maintenance or repair work is carried out on this unit by personnel who
have not been trained by REHM and thus are not authorised to carry out
the work, this will void your guarantee and warranty claims over REHM.
Before starting to clean the welding unit, it must be switched off and taken
from the power network!
Before starting maintenance work on the welding unit, it must be switched
off and taken from the power network and secured against accidental
reactivation.
Supply lines must be capped and switched to without pressure.
The warning notes given in  Chapter 2 "Safety" must be taken into
account.
The welding unit and its components are to be maintained in accordance with the
specifications made in the maintenance table.
Insufficient or incorrect maintenance or repairs can lead to disruptions in
operation. Regular maintenance of the unit is thus essential. No structural
changes or additions may be made to the unit.