▶ When replacing the button-cell battery, make sure that the correct
procedure is followed. There is a risk of explosion.
▶ Use only the button-cell batteries stated in these operating instruc-
tions. Do not use any other button-cell batteries or other power supply.
▶ Do not attempt to recharge button-cell batteries and do not short-
circuit button-cell batteries. The button-cell battery can develop a
leak, explode, catch fire and injure persons.
▶ Remove and dispose of discharged button-cell batteries correctly.
Discharged button-cell batteries can develop leaks and so damage the
product or injure persons.
▶ Do not allow the button-cell battery to overheat and do not throw it
into a fire. The button-cell battery can develop a leak, explode, catch
fire and injure persons.
▶ Do not damage button-cell batteries and do not attempt to take
button-cell batteries apart. The button-cell battery can develop a leak,
explode, catch fire and injure persons.
▶ Do not bring a damaged button-cell battery into contact with water.
In the presence of water, escaping lithium can produce hydrogen and so
lead to a fire or an explosion, or cause injury to persons.
3
Technical data
Frequency, radar sensor
Maximum transmitting
power, radar sensor
Frequency, inductive sensor 48 kHz ... 52 kHz
Maximum magnetic field
strength (at 10 m)
4
Switching measuring tool on/off
Before switching on the measuring tool, check that the sensor area is
not damp. If necessary, wipe the measuring tool dry with a cloth.
1. To switch the measuring tool on, press the on/off button or the start/stop
button.
▶ Outside the operating temperature range, a fault message is dis-
played and the measuring tool automatically switches off. Allow the
measuring tool to cool down or warm up, as appropriate, and then
switch it on again.
The tool automatically switches itself off completely if it is not used
for 5 minutes. You can change this preset delay before automatic
deactivation in the main menu.
*2327817*
1.8 GHz ... 5.7 GHz
0.00001 mW
20 dBµA/m
2327817
English
15