LA 1118CP
7

Assembly

7.1 General

The following connections need to be established on the heat
pump:
Heating system flows and returns
Condensate drain
Communication line to the heat pump manager (controller
-N1)
Power supplies (load/control voltage)
NOTE
When setting up and installing the heat pump system, it must
be ensured that the heat pump casing is intact and any
tampering with the heat pump casing must be refrained from.
In particular, misuse of the heat pump casing (e.g. as a
mounting or similar) must be prevented.
DANGER!
Risk of death due to lightning.
Standing outside during a storm can result in a risk of death.
Do not stand in the immediate vicinity of the heat pump.
DANGER!
Risk of death due to electric shock.
There is a risk of death when working on the electrical
equipment or live components in wet weather conditions
(precipitation, snow).
In case of precipitation, the device must be properly
closed.
WARNING!
Risk of injury.
When working on the device without protective equipment,
injuries can occur, e.g. cuts.
Use
of
personal
protective
accordance with DGUV regulation 100-500 Chap. 2.35
Personal protective equipment consisting of safety
gloves, safety shoes, safety glasses and long clothing that
fully covers the body.
www.dimplex.de
equipment
(PPE)
in
452171.66.01-EN · FD 0212

7.2 Opening the covering panels

7.2.1 Opening the grid panels
Removing the grid panels on the front and rear:
Loosen the screws at the top of the corresponding panel
(1).
Tilt the upper panel approx. 30° forwards (2)
Pull the panel diagonally upwards out of the pedestal (3)
Fig. 7.1:Opening the grid panels
7.2.2 Opening the side covering panels
Removing the side covering panels:
Loosen the screws at the top of the corresponding panel
(1)
Tilt the upper panel approx. 30° forwards (2)
Fig. 7.2:Opening the side covering panels, work step 1 and 2
In the tilted position, slide the panel approx. 40 mm to the
right as far as it will go (3)
3.
Fig. 7.3:Opening the side covering panels, work step 3