BVS ID-M1280xF1-xx-xxx
Device Temperature Alarm Configuration
Setting for the lower threshold value (in °C) for the device temperature warning (0x8D20) and upper threshold
value (in °C) for the device temperature warning (0x8D10).
Events
Event
Event Type
Code
0x4000
Error
(16384)
0x4210
Warning
(16912)
0x4220
Warning
(16928)
0x8D10
Warning
(36112)
0x8D20
Warning
(36128)
Variant Dependence
The functionality is available in all variants.
Event – Description – Remedy
Temperature Fault – Overload – The BVS ID is operated outside
of the device-specific temperature limits. Risk of device
damage.
Device Temperature Overrun – Clear Heat Of Source – Risk of
device damage. The BVS ID is too hot. 
→ Remove heat source, provide the BVS ID e with heat
insulation if necessary.
Device Temperature Underrun – Insulate Device – Risk of device
damage. The BVS ID is too cold.
→ Insulate the BVS ID.
Device Temperature Upper Warning – The set upper
temperature warning threshold has been exceeded.
Device Temperature Lower Warning – The set lower
temperature warning threshold is below the minimum value..
Device Status
4 – Failure
2 – Out-of-Specification
2 – Out-of-Specification
0 – Device is operating properly.
0 – Device is operating properly.