4.4.9.2 Operating Hours Counter

Description
The operating hours counter can record the operating hours of a device accurately to the second. There is a
total of three operating hours counters. In addition to an operating hours counter for the operating hours since
the 
start of the device, there is a total operating hours counter and a customer-specific operating hours counter that
can be reset. The storage interval is configurable and the operating hours are not stored once 1,000,000
storage cycles have been reached.
The output of the operating hours can serve as a time control for the service interval as well as for preventative
maintenance. Schedules for regular service can be tied to the operating hour values. Moreover, a high value of
the total operating hours is indicative of intensive use of the BVS ID and possible deterioration of the
performance. The risk of failure can be countered preventatively through replacement.
Algorithm
While the counter is incremented every second, the storage interval doubles after each save operation. Starting
with a save operation after 1 minute, then after 2 minutes, then after 4 minutes, then after 8 minutes, up to a
maximum storage rate of 12 minutes.
Process Data
Object ID
0x001B (27)
Current Operating Hours
0x001C (28)
Total Operating Hours
0x001D (29)
Custom Operating Hours
ISDU
Name
Index
Operating Hours
Counter
Current Operating
Hours
0x0057
(87)
Total Operating Hours
Custom Operating
Hours
Operating Hours Saving
0x0074
Mode
(116)
NOTE
The maximum counter value that can be saved is 1,000,000 and, with a switch-on and switch-off every
12 minutes (with static counter), this means a service life of over 20 years. If switched on and off more
frequently or in the case of dynamic storage, the maximum storage time is reduced depending on the
application.
Current Operating Hours
This parameter saves the value of the operating hours since the last commissioning in seconds.
Total Operating Hours
This parameter saves the value of the operating hours since the first commissioning in seconds.
Name 
Output of the current operating hours counter
Output of the total operating hours counter
Output of a user-defined operating hours counter
Subinde
Acces
Length
x
s
12
0
R
bytes
1
R
4 bytes
2
R
4 bytes
3
R
4 bytes
0
R/W
1 byte
Description
Data
Data Type
Storage
n/a
UINT32
n/a
-
UINT32
n/a
-
UINT32
n/a
-
UINT8(ENUM
Yes
0
)
Direction
Input
Input
Input
Default
english 
123