If a switching signal is not output at the switching
terminal
Some VCR models may not output a switching signal
in 3H or 6H mode. In such a case, make the settings as
indicated in the table below.
VCR SET menu
settings
REC SPEED
ALARM REC SPEED
Note
When the recording speed is set to F3 or F6, the alarm
recording speed is fixed to 3H or 6H. Therefore, when
using a recording speed other than 3H or 6H, do not
use the F3 or F6 setting.
SERIAL SET
Connect the multiplexer to a computer, using a 9-pin
D-SUB cable (not supplied), then set the maximum
communication speed between the unit and the
computer.
For detailed information, please refer to "Command
Reference" on page 62 (GB).
Setting the RS-232C/RS-485 communication
1
Press the MENU button 3 times. Press the v button
to go to the (SERIAL SET) menu.
2
Using the + (or –) button, select the desired
"DATA SPEED" setting, then press the v button.
3
Using the + (or –) button, select the desired
"ALARM SEND" setting.
Timelapse
Real time
VCR
VCR
3 (3H)
6 (6H)
F3
F6
4
Press the MENU button to go to the next menu
screen, or
Press the EXIT button to exit the menu display.
(SERIAL SET) menu
DATA SPEED (Default setting: 19200 bps)
The available settings are: 2400, 4800, 9600, 19200
bps
ALARM SEND (Default setting: OFF)
ON: The alarm information is output at the RS-232C/
RS-485 connectors.
OFF: The alarm information is not output at the RS-
232C/RS-485 connectors.
Unit address confirmation
If multiple units are going to be controlled through a
system controller (not supplied) via the RS-485
connection, each unit must have an address for remote
control purposes. The address set for the unit can be
checked by accessing the (VCR SET) menu.
1
Press the MENU button 3 times to display the
(VCR SET) menu.
The unit address is displayed on the last line of the
menu. The unit address can be set using the
interface setting DIP switches on the back panel of
the unit. (see page 62 (GB))
2
Press the MENU button to go to the next menu
screen, or
Press the EXIT button to exit the menu display.
(interface setting DIP switches)
ON
OFF