MIK
0x0426 UserUnit
0x043F SimMode
0x0440 SimStartValue
0x0444 SimIncrementValue
0x0448 SimNumberIntervals
0x044A SimTimingIntervals
0x044C ValueInSiUnit
Legende:
MRE - Measuring Range End
MRS - Measuring Range Start
Seite 38
User Unit used for
1,0
part volume
Mode of the
Simulation:
0
Static, Triangle or
Monotonic
Value to start with
0,0
the simulation
Incrementation
value of the
10,0
simulation
Number of intervals
20
to simulation
Timinig in ms
50
between intervals
Saved part volume
0,0
value in SI unit
9999,9
0,001
4
(1) ‐ Static
(2) ‐ Triangle
1
(3) ‐ Monotonic
99999,99
‐99999,99
4
99999,99
‐99999,99
4
65000
1
2
50000
10
2
999999,0
‐999999,0
4
FloatT
R/W
UInteg
R/W
erT
FloatT
R/W
FloatT
R/W
UInteg
R/W
erT
UInteg
R/W
erT
FloatT
R
MIK K18/0323