Overview of IO-Link Data and Functions (continued)
Name
Process Data Profile
selection
Process Data Input
Descriptor
Process Data Output
Descriptor
Last Valid Process Data
Inputs
Last Valid Process Data
Outputs
Profile Characteristic
Device Access Locks
Tab. 3-2:
ISDU – Identification Data
3.5
System Commands
Command Value
0x40 (64)
0x41 (65)
0x42 (66)
0x43 (67)
0x44 (68)
0x45 (69)
0x46 (70)
0x47 (71)
0x48 (72)
0x49 (73)
0x4A (74)
0x4E (78)
0x4F (79)
0x80 (128)
24
english
Index
Sub-
Access
index
Process Data Information and Configuration
0x0051
0
R/W
(81)
0x000E
0
R
(14)
0x000F
0
R
(15)
0x0028
0
R
(40)
0x0029
0
R
(41)
Profile Characteristic
0x000D
0
R
(13)
Device Access Locks
0x000C
0
R/W
(12)
Device Action
Teach Apply – Calculates the switching point for SP1, SP2.
Teach SP1 – Determines teach point 1 for setpoint 1 and calculates the switching point.
Teach SP2 – Determines teach point 1 for setpoint 2 and calculates the switching point.
Teach SP1 TP1 – Determines teach point 1 for setpoint 1
Teach SP1 TP2 – Determines teach point 2 for setpoint 1
Teach SP2 TP1 – Determines teach point 1 for setpoint 2
Teach SP2 TP2 – Determines teach point 2 for setpoint 2
Teach SP1 Start – Starts dynamic teach-in for setpoint 1
Teach SP1 Stop – Stops dynamic teach-in for setpoint 1 and calculates the switching point.
Teach SP2 Start – Starts dynamic teach-in for setpoint 2
Teach SP2 Stop – Stops dynamic teach-in for setpoint 2 and calculates the switching point.
Teach Reset – Any active teach-in process is interrupted, all temporarily stored values are reset.
Teach Cancel – Any active teach-in process is interrupted.
Device Reset – Device Reset means a warm start of the device. During this process, the
microcontrollers are restarted and all initializations performed again without any change made to
the parameter values (see chapter 7.3 on page 96).
Length
Data Type
1 byte
UINT8(ENUM)
= PD input
UINT8[]
data length
= PD
UINT8[]
output data
length
Variant 1/2:
1 byte
Variant 3:
17 bytes
Variant 4:
6 bytes
Variant 5:
17 bytes
1 byte
Variant 1:
UINT16[]
12 bytes
Variant
2...5:
20 bytes
2 bytes
UINT16
Data
Default
Storage
Yes
1
n/a
n/a
n/a
n/a
n/a
Yes
0