BOS R254K-UUI-LK10-S4
Photoelectric Sensors
5
Primary Device Functions (continued)
5.2
Device Discovery
5.2.1
Description
With the Device Discovery function, an IO-Link device can
be found again by starting signaling on the LED of the
device by means of a system command.
5.2.2
ISDU
Name
Device Discovery Timeout
Tab. 5-2:
Device detection – ISDU
Device Discovery Timeout
The Device Discovery Timeout parameter sets the duration
of the Device Discovery signal that is displayed via LEDs.
The value is specified minutes. The value range from 0 to
30 minutes is allowed. If the parameter is set to 0, the
Device Discovery signal is deactivated. The parameter is
reset by Application Reset and Factory Reset (also see
section Reset Commands on page 96).
5.2.3
System Commands
Command Value
Device Action
0xAF (175)
Start Device Discovery
Tab. 5-3:
Device detection – System Commands
www.balluff.com
Index
Subindex
0x00FE (254)
0
Access
Length
Data Type Data Storage
R/W
2 bytes
UINT16
Default
Yes
1
english
29