70/83
Bosch Rexroth AG
Status codes
of the inputs „Fault reset", "Reset fault with Weld complete" or "Reset fault and
reweld" is activated.
8
Status codes
Tab. 11: Status codes
Code (decimal)
Meaning
00
OK
80
Stop circuit open / no +24 V
81
Weld without command
85
Memory deleted == RAM checksum error
86
Data download active
87
no welding program == invalid parameters
88
Hardware fault
89
I/O bus fault (only for timers with a serial I/O bus)
90
Halfwave monitoring
91
Main switch tripped
92
External temperature too high
93
Synchronization error
94
Start inhibited
95
Program parity error
98
Programmed value too large
99
Welding process error
100
Supply voltage fault
160
Excessive heat sink temperature
164
Transformer temperature too high
165
Hardware fault driver module
166
24V Supply voltage fault
182
Dressing tool control not OK
224
Dressing result not OK after first check
225
Dressing result not OK after second check
3106
Q-Stop component
3107
Q-Stop spot in series
3108
Q-Stop special spot
3109
UIP: Violation of the absolute lower tolerance level
3110
PSF: Violation of the absolute lower tolerance level
3111
UIP: Violation of the absolute upper tolerance level
3112
FQF: Violation of the absolute lower tolerance level
3113
FQF: Violation of the absolute upper tolerance level
R911334336 | PSI 6xCx.225