3.10

Electrical connection

Check the fusing (fuse) of your electrical supply according to the technical instructions
regarding the total connected power of the lathe.
Firmly connect the machine.
ATTENTION!
Ensure that all 3 phases (L1, L2, L3) and the ground wire are connected correctly.
The neutral conductor (N) of its power supply is not connected.
ATTENTION!
Make sure that the direction of rotation of the drive motor and cooling lubricant pump is
correct. If the rotational direction switch is switched to the down position, the lathe
spindle must rotate anticlockwise. If necessary, exchange two phase connections. The
guarantee will become null and void if the machine is connected incorrectly.
3.10.1 Electrical connection TH5615 │ TH5620 │TH5630
The lathe TH5615 │ TH5620 │TH5630 is designed for connection to all networks.
3.11

Warming up the machine

ATTENTION!
If the lathe and in particular the lathe spindle are immediately operated at maximum load
when cold, this may result in damages.
If the machine is cold, e.g. directly after having transported the machine, it should be warmed
up at a spindle speed of only 500 1/min for the first 30 minutes.
3.12

Functional check

Check if all spindles are running smoothly.