Herunterladen Inhalt Inhalt Diese Seite drucken

Display Messages - Dometic TEC60 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TEC60:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operating the generator
7.6

Display messages

Display message
Description
LOW BATTERY
The battery voltage has fallen
below the minimum value for
starting up (9V).
Check OIL Level
OIL CHANGE
The number of prescribed
operating hours has been
reached for changing the
engine oil.
NO FUEL
The petrol in the tank is in
reserve.
OIL ALERT
Insufficient engine oil.
GENERATOR ALERT!
General alarm message
Example: The control ring on
the throttle valve of the carbu-
rettor (stepper motor) is
faulty.
OVERLOAD!
The consumers generate an
overload at the output.
SHORT CIRCUIT
The consumers cause a short
circuit at the output.
OVER TEMPERATURE
Overheating
36
Generator behaviour
The generator does not start.
The generator continues to
run.
The generator continues to
run.
The generator continues to
run.
The generator stops.
The generator stops.
The inverter switches off,
therefore no voltage is sup-
plied but the engine carries
on running until it goes off.
The inverter switches off,
therefore no voltage is sup-
plied but the engine carries
on running until it goes off.
The inverter switches off so
no voltage is supplied to cool
the generator, but the engine
carries on running.
Measures
Charge the battery.
Fill up with oil (see chapter
"Checking the oil level" on
page 39).
Change the oil (see chapter
"Changing the oil (fig. 6,
page 4)" on page 43), then
confirm the message by
pressing and holding down
the button START/STOP.
Restart the generator by
again pressing and holding
down the button
START/STOP.
Refuel.
Fill up with oil (see chapter
"Checking the oil level" on
page 39).
Check the system by referring
to the troubleshooting table.
If the problem persists, con-
tact the manufacturer's
branch office in your country
(addresses on the back
page).
Reduce the connected load
and start the generator again.
Check the connected con-
sumers then start the genera-
tor again.
Leave the engine to cool
down for a few minutes then
start the generator again.
TEC60
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis