Technical description
6
Technical description
The TEC60 generator consists of the following main parts (fig. 1, page 2):
Power generator with permanent magnets (1)
Combustion engine (2)
Connection box (3)
Inverter (4)
Control panel (5)
The combustion engine (2) drives the power generator connected to it (1),
which in turn generates AC voltage.
The external inverter (4) transforms this AC voltage into a stable voltage of
230 V and 50 Hz, which is available at the inverter terminal. The socket for
the connection cable to the control panel is installed in the inverter.
The terminals and the main switch are installed in the connection box (3) lo-
cated behind the door.
The control panel is used to operate the device (5).
The generator has an integrated battery charger for charging the connected
battery.
Control elements in the connection box
The connection box is located on the generator behind the cover.
No. in
fig. 2,
Description
page 2
1
Main switch
2
Thermal protection of the
inverter
32
Switches the generator to standby or no
function.
Activates if the inverter overheats (see
chapter "Display messages" on page 36)
TEC60
EN