6.5
Power-up and output signal in the event of a fault
7
Transport and storage
7.1
Storage
8
Technical data
9
Conformities and certificates
8028139/2022-11-22 | SICK
Subject to change without notice
During power-up, the signal output for analog devices is ≥ F.S.O = Full Scale Output.
After that the device is ready for use. The signal output is only available to CANopen®
devices after the boot-up time.
Table 25: Operational statuses and output signal
Output variant
4 ... 20 mA
0 ... 10 V
CANopen®
Fault:
a)
Missing position magnet
b)
Position magnet in zero or damping zone
c)
Malfunction or failure of the magnetostrictive element
During the power-up delay
(see „Technical data", page
defined as an unusable signal. The machine controller must take this into consideration
in its processing. After the power-up delay, the linear encoder is ready for operation. The
output signal behaves as described in the event of a fault.
Store the device under the following conditions:
•
Recommendation: Use original packaging.
•
Do not store outdoors.
•
Store in a dry area that is protected from dust.
•
To allow any residual dampness to evaporate, do not package in airtight contain‐
ers.
•
Do not expose to any aggressive substances.
•
Protect from sunlight.
•
Avoid mechanical shocks.
•
For storage periods of longer than 3 months, check the general condition of all
components and packaging on a regular basis.
You can obtain the technical data (specification parameters, dimensional drawings,
STEP files and information on suitable accessories as well as the current operating
instructions for the product at www.sick.com. To do so, enter the product part number
in the search field (part number: see the entry in the "P/N" or "Ident. no." field on the
type label).
You can obtain declarations of conformity, certificates, and the current operating
instructions for the product at www.sick.com. To do so, enter the product part number
in the search field (part number: see the entry in the "P/N" or "Ident. no." field on the
type label).
Output signal
During the power-up
(≥ F.S.O)
Bootup message
51), the output signal is
QUICKSTART
If an error occurs
> 21 mA
> 10.8 V
Position value = 0xFFFFFFFF
and EMCY message
Q U I C K S T A R T | DAX®
en
51