Operation ILR11xx
All parameters can be adjusted and measured values can be read via the integrated serial interface using PC
software or your own special application program. Parameters of the RS422 interface can only be altered on
the sensor.
In measuring mode
DIST mm
- the text "DIST mm" or "DIST INCH" (depending on unit selected) and the actual measured
127045
value are displayed on the display.
Selecting menu items
Menu items are displayed in two
1. < Menu item> With this display it is possible to switch to another menu item with
, or select the menu point with
2.
Menu item With this display the keys
When the sensor is switched on the sensor type and the software revision number appears
ILR1xxx
for approx. 2 sec.
Rev. nnnnn
The software revision number must always be quoted when contacting the
manufacturer with technical queries.
forms:
.
can be used to alter the value.
IMPORTANT!
The red target laser
and the display back-
ground lighting are
always active in set-up
mode.