NOTE: See the following table for information on the recommended welding current to be used,
depending on the electrode diameter.
Ø Electrode
Welding current
1.6 mm
40–60 A
2.0 mm
60–80 A
2.5 mm
80 A
ATTENTION: Do not bring the earth terminal
contact with one another.
Hold the welding mask
To stop the procedure, set the ON/OFF switch
ATTENTION: When the thermal sensor is triggered, the yellow control lamp
case, it will not be possible to continue welding. The device will continue to run so that the fan can cool
the device. As soon as the device is ready for operation again, the yellow control lamp
automatically. The welding function can now be used again.
ATTENTION: Make sure that you do not rub the electrodes. Doing this can damage the workpiece
and make it more diffi cult to ignite the arc. After the arc is ignited, maintain the correct gap from the
workpiece. The distance should be appropriate to the diameter of the electrode used. When welding
maintain this gap as accurately and consistently as possibly. The angle between the electrode and the
direction of operation should be between 20° and 30°.
ATTENTION: The welding clamp and welding electrodes must be placed on the insulated bracket
after welding. Wait until the electrode is cooled before removing the welding slag. To weld an intermittent
weld seam again you must fi rst remove the welding slag at the welding position.
ATTENTION: A voltage which is 10% below the rated input voltage of the welder can have the
following consequences:
The power to the device will reduce.
The arc stops or becomes unstable.
ATTENTION:
The arc radiation can lead to infl ammation of the eyes and skin burns.
Casting and welding slag can cause eye injuries and burns.
Wear tinted safety goggles or a protective mask.
The safety mask must meet the EN175 safety standards.
It is essential that you only use the welding cable which is included with the delivery (10 mm
16
GB/IE/NI
in front of the face and start the welding procedure.
7
and the electrode holder
4
to the "O" ("OFF") position.
9
/electrodes into direct
5
lights up. In this
2
will switch off
2
).
2