3. General information

3.1 Technical data

Max. display range
Max. display resolution
Max. approved resolution
Division
Calibration unit
Weighing units
Display
Accuracy
Power supply
Work current
Functions
Zero range
Tare range
Stabilization time
Keypad
Operating temperature
Humidity range
Load cell excitation voltage
Load cell drive
Recommended actual scale
interval (d)
Max. load cell excitation
Signal connection
Real clock
Dimensions of scale
Dimensions of terminal
0.0001, 0.0002, 0.0005 to 10, 20 ,50
6-digit, 7-segment, 25 mm height
or AC adapter: 9V DC / 600 mA with central positive
≤ 15 mA (backlight off, no load cells)
≤ 30 mA (backlight on, no load cells)
≤ 50 mA (backlight on, one load cell)
Normal weighing, counting, percent weighing,
check weighing, BMI, Hold, Accumulation
[HOLD/SETUP], [PRINT/FUNC], [ACC/TOTAL],
[UNIT/DATA], [TARE/PRESET], [ZERO/ON/OFF]
< 90% relative humidity, non-condensing
4 or 6 lead with sense leads
built-in nonvolatile real time & date
1.043,5 x 1.010 x 63 mm per platform
resp. 2.087 x 1.010 x 63 mm complete scale
with bracket: 250 x 125 x 70 mm
without bracket: 200 x 95 x 45 mm
-999,999 to 999,999
1:100,000 (primary unit)
1:125,000 (second unit)
1:5,000
kg or lb
g, lb, lb:oz, g, oz, pcs, %
LCD with blue backlight
≤ 0.01 %
4x AA batteries
programmable zero range
full capacity
< 3 seconds
-10° to 40°C
5V DC
-3mV/V to 3mV/V
> 1 uV / display division
60 mA