3.1 Back Panel External Connections – Standard Accessories
LAN (for
future use)
USB connectors
Power
for printer, PC-
connector
connection &
keyboard
The back panel contains all the rest of the main connectors (sockets):
Special notes:
The HLS (hearing loss simulator) connector is currently not used. Use the Standard Headphone
and HF Headphone connectors for HLS. This is prepared for future use.
In addition to the standard DD45 headset, four other air conduction transducers may be used
(they all connect to specific outputs on the AC40):
HDA300: High Frequency requires a HF headset.
CIR33 for insert masking: Insert phone CIR33 for insert masking has a limited sound
quality, making it only adequate for masking noise presentation.
EAR-Tone 3A or 5A general purpose insert phone: Insert headphone EAR-Tone 3A or
5A are high quality transducers that may be used instead of the DD45/TDH39. It
improves cross hearing from the normal approximately 40dB of the TDH39 to
approximately 70dB. Masking as well as avoiding over-masking is thus easier with this
type of headphone.
IP30 insert phone is the standard insert phone with same properties as EAR-Tone 3A
Currently FF3/FF4 (both the powered and non-powered) is not used. This is prepared for future
use.
Assistant Monitor: There is always a direct connection through the goose neck microphone to the
assistant wearing a headset connected to the "Assistant Monitor" output.
The LAN connection is currently not used for any application (only internally in production).
Mic 2: Please refer to the section about Patient Communication (Talk Forward and Talk Back).
When using the HDMI output the output resolution will be the saved as on the build in 8,4 inch
display: 800x600.
CD-input: It is required that any attached CD-player has a linear frequency response in order to
comply with the requirements of IEC 60645-2.
USB connections is used for:
PC connection to Diagnostic Suite (the large USB connector)
Direct print
PC-keyboard (for entering client names)
Amplified
Free Field
outputs
(2x20
High Freq.
watt) –
Left / Right
only
FF3/FF3
HDMI output
Free Field 1
for external
and 2
monitor (e.g.
(external
for patient
amplificatio
counceling)
n needed)
Patient
Response
Switch 1 / 2
Insert
masking
Bone conductor
B81 /B81
1 / 2
Standard
Standard
Headphones
Insert Phone
DD45/TDH3
EarTone 3A /
9/HDA300
IP30
Page
10
Assistant
Monitor
Control
output
Extra Talk
External
For
forward
CD / MP3
Talk
mic., e.g.
input
Back
for table
Speake
mic.