Fig. 7
If no live image appears, check the following points:
No obstruction in front of the lens
Sufficient lighting (parameter „Lighting = on" or external lighting)
Correct shutter setting (see page 67, correct focus setting, see section 6)
If the live image still fails to appear, contact the Service dept.
Carry out fine adjustment of the FA45 Code Reader with „GOOD" parts to avoid interfering effects.
6. Adjusting image focus. To adjust image definition, turn the focussing screw at the rear of the housing
(fig. 2, page 54) in clockwise direction (object distance more) or anticlockwise direction (object distance
less). Check the position of the FA45 Code Reader and adjust if necessary.
The FA45 Code Reader is now ready for use.
Before using the FA45 Code Reader, it should be prepared for the scanning task with the assistance of the PC
software.
A general description of the software is given below.
58