09.02
PNU
OP1S parameter name
Description
*
: Conf.
Par.
P612
Trg Bit Contact
Destination of the status bit 'Energize main contactor' (status word 1, bit 12)
*
H level: energize contactor!
Important: Relay X9-4/5, whose function cannot be programmed, is
provided for controlling the main contactor.
Parameter values, indices: as P600
PNU=264Hex; Type=L2; Scaling: 1Hex
P613
Trg DC V reduced
Destination wiring for the status bit "U
*
(status word 1, bit 13)
Parameter values, indices: as P600
PNU=265Hex; Type=L2; Scaling: 1Hex
P614
Trg Motor/Regen
Destination wiring for the status bit "Regenerative/motoring mode" (status
*
word 1, bit 14)
**
Parameter values, Indices: as P600
PNU=266Hex; Type=L2; Scaling: 1Hex
P618
Trg Current Lim.
Destination wiring of the status bit "Current limit active"
*
(status word 2, bit 18)
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken-wire proof).
Parameter values, indices: as P600
PNU=26AHex; Type=L2; Scaling: 1Hex
P619
Trg Bit Ext Flt1
Destination of the status bit 'External fault 1' (status word 2, bit 19)
*
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken wire proof).
Parameter values, indices: as P600
PNU=26BHex; Type=L2; Scaling: 1Hex
P620
Trg Bit Ext Flt2
Destination of the status bit 'External fault 2'
*
(status word 2, bit 20)
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken wire proof).
If an ON command is active, L-level causes fault trip after 200 msec.
Parameter values, indices: as P600
PNU=26CHex; Type=L2; Scaling: 1Hex
P621
Trg Bit ExtWarn
Destination of the status bit 'External warning'
*
(status word 2, bit 21)
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken wire proof).
Parameter values, indices: as P600
PNU=26DHex; Type=L2; Scaling: 1Hex
Siemens AG
6SE7087-6AK85-0AA0
Common Rectifier
Operating Instructions
∧ 1
=
reduced"
d
∧ 1
=
∧ 1
=
∧ 1
=
∧ 1
=
∧ 1
=
∧ 1
=
Value range
Display
[phys. unit]
Indices
Selection text
Factory-
setting
0 to 4212
2
0
0 to 4212
2
0
0 to 4212
2
0
0 to 4212
2
0
0 to 4212
2
0
0 to 4212
2
0
0 to 4212
2
0
ENGLISH
Parameter List
See
Modify
(access /
status)
3/
BR
3/
BR
3/
ABR
3/
ABR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
5-25

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis