The Troubleshooting table indicates measures to be taken if the sensor stops working.
LED indicator/fault pattern
Green LED flashes
Switching outputs do not
behave in accordance with
table 4
Light spot is aligned to the
background, no object in
beam path, yellow LED does
not light up
Light spot is aligned to the
background, object in beam
path, yellow LED lights up
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
A71
A72
V1.1
2 bytes
Byte 0: bits 15... 8
Byte 1: bits 7... 0
Q
/ Boolean
L1
/ Boolean
Qint.1 /
Boolean
2 ...15 /
2 ... 15 /
2 ... 15 /
[counter
[length /
value] /
speed
value] /
UInt 14
measure‐
UInt 14
ment] /
SInt14
Cause
IO-Link communication
1. Change of the configuration
2. Short-circuit
The sensing range distance is
too large
Sensing range is set too low
A73
A75
4 bytes
Byte 0: bits 31...
24
Byte 1: bits 13...
16
Byte 2: bits 15...
8
Byte 3: bits 7... 0
Q
/
Qint.1 / Boolean
L2
Boolean
2 /
2 ... 7 / [empty]
Qint.1 /
Boolean
3 ... 15 /
8 ... 31 / [carrier
[time mea‐
load] / UInt 24
surement
value] /
UInt13
Measures
None
1. Adjustment of the configura‐
tion
2. Check electrical connections
Reduce the sensing range
(Rotate to the left)
Increase the sensing range
(Increase the sensing range)