OPERATING INSTRUCTIONS
6.3
Setting
en
7
Troubleshooting
7.1
Troubleshooting table
24
O P E R A T I N G I N S T R U C T I O N S | GRL18(S)V
Table 3: Definition of sensing range
2
PL80A
1
PL40A
2
PL20A
3
P250
4
PL22
5
REF-Plus 3436
6
Sensitivity setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
The sensitivity is adjusted with the potentiometer (type: 270°). Clockwise rotation:
operating reserve increased; counterclockwise rotation: operating reserve reduced. We
recommend setting the potentiometer to "Maximum". A lower operating reserve may be
necessary for depolarizing surfaces.
The sensor is adjusted and ready for operation.
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 4: Troubleshooting
LED/fault pattern
Green LED does not light up
Green LED does not light up
Green LED does not light up
GRL18(S)V
0.03 ... 7.2 m
0.03 ... 6.2 m
0.03 ... 3.8 m
0.03 ... 6.4 m
0.03 ... 2.2 m
0.06 ... 2.0 m
Cause
No voltage or voltage below
the limit values
Voltage interruptions
Sensor is faulty
Measures
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Ensure there is a stable power
supply without interruptions
If the power supply is OK,
replace the sensor
8021183.1HT2/2023-02-13 | SICK