8.4.3.42.5 Attribute 209, Preset (process data) Status
This attribute is only used as a container to map the "Preset Status Byte" into the
process data. It is not intended to be set or read out via the acyclic data.
Data type
Access
Value
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class
8.4.3.43 Attribute 210 to 212, Position Limit Output
The attributes 210 to 212 for the limit switch function are currently not supported.
8.4.3.44 SSI Output
The SSI output is optional and must be supported by the measurement system
hardware.
8.4.3.44.1 Attribute 215, SSI available
SSI available indicates if the optional SSI interface is available.
Data type
Access
Value
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class
8.4.3.44.2 Attribute 216, SSI Code
SSI Code defines the output code for the SSI interface.
Data type
Access
Value
Printed in the Federal Republic of Germany
03/10/2020
BYTE
Get
0x00 = Preset via process data is not performed
0x01 = Preset via process data is performed cyclically
0x80 = invalid preset value
0x23
0x24
Logical Type
Class #23
= Instance
BOOL
Get
0 = SSI output is not available
1 = SSI output is available
0x23
0x24
Logical Type
Class #23
= Instance
BYTE
Set / Get
0 = Gray
1 = Binary
2 = Gray cut
TR - ECE - BA - DGB - 0135 - 04
0x01
0x30
Logical Type
Instance #1
=Attr.-ID
0x01
0x30
Logical Type
Instance #1
=Attr.-ID
TR-Electronic GmbH 2017, All Rights Reserved
0xD1
Attr.-ID #209
0xD7
Attr.-ID #215
Page 171 of 200