8.2.3.1 Attribute 5, Status
Status returns the summary status of the measuring system:
Bit
0
1
2
3
4-7
8
9
10
11
12-15 -
Bit definitions for extended device status field
Bits 4-7
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010-1111
Printed in the Federal Republic of Germany
03/10/2020
Called
Definition
Owned
Under EtherNet/IP™ without meaning
-
0, reserved
TRUE: Indicates the application of the device has been
Configured
configured to do something different than the
"out–of–box" default.
-
0, reserved
Extended
see table below
Device Status
TRUE: Indicates the device detected a problem with
Minor
itself, which is thought to be recoverable. The problem
Recoverable Fault
does not cause the device to go into one of the faulted
states. See Behavior section.
TRUE: Indicates the device detected a problem with
Minor
itself, which is thought to be unrecoverable. The
Unrecoverable
problem does not cause the device to go into one of the
Fault
faulted states. See Behavior section.
TRUE: Indicates the device detected a problem with
Major
itself, which caused the device to go into the "Major
Recoverable Fault
Recoverable Fault" state. See Behavior section.
Major
TRUE: Indicates the device detected a problem with
itself, which caused the device to go into the "Major
Unrecoverable
Unrecoverable Fault" state. See Behavior section.
Fault
0, reserved
Description
Self-Testing or unknown
Firmware update in progress
At least one faulted I/O connection
No I/O connections established
Non volatile configuration bad
Major Fault – either bit 10 or bit 11 is true (1)
At least one I/O connection in run mode
At least one I/O connection established, all in idle mode
0, reserved
0, reserved
0, not supported
TR - ECE - BA - DGB - 0135 - 04
TR-Electronic GmbH 2017, All Rights Reserved
Page 131 of 200