Runtime Statistics
Parameters::Device Manager::Runtime Statistics
PNO
Parameter Descriptions
1139
Control Board Up Time
The time in seconds for which the control board has been powered, either by 24v or from the 3-phase supply.
1252
HV SMPS Up Time
The time in seconds for which the drive has been powered from the 3-phase supply.
1406
HV Power On Count
The number of times that the drive has been powered up from the 3-phase supply
1407
Motor Run Time
The time in seconds for which the drive has been controlling a motor
Functional Description
The Runtime Statistics group of parameters indicate the working age of the drive. The Control Board Up Time value is used as a reference when
recording the time at which a trip occurs. Similarly, the HV SMPS Up Time is used as a reference when recording the time at which a disabled trip
event occurs when the drive is operating in Fire Mode, (see Chapter 13: Fire Mode,
on page D-118 and HA502134U002 "Fan Control Application" manual).
AC30V series Variable Speed Drive
D-94
Parameter Reference