Herunterladen Inhalt Inhalt Diese Seite drucken

Description/ Introduction; Introduction; Inspection; Items Included - Bovie Smoke Shark III Bedienungsanleitung

Chirurgische rauchabzugsvorrichtung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 63

1.1 Introduction

The Bovie
Smoke Shark Surgical Smoke Evacuator is intended to evacuate and filter surgical smoke and
®
aerosols created by the interface of surgical tools with tissue (examples: lasers, electrosurgery systems,
desiccators and ultrasonic devices).
The Bovie
Smoke Shark Surgical Smoke Evacuator has been designed to provide appropriate
®
suctioning, using a motor on /off button, to manage surgical smoke instruments. The ultra-quiet motor
is used to draw the surgical smoke from the surgical site through the vacuum tubing and into the filter
where the surgical smoke is processed through four (4) stages of filtration. A single, completely enclosed,
disposable filter is used to simplify installation and removal during filter changes to protect healthcare
personnel from potential contamination during filter changes.
1.
The first stage filtration utilizes a pre-filter to trap and remove gross particulate and casual fluid.
2.
The second stage filtration is an ULPA grade (Ultra Low Penetration Air) filter with a high-tech
patented design that captures particulates and micro-organisms from 0.1 to 0.2 microns at 99.999%
efficiency.
3.
The third stage filtration uses the highest grade virgin activated carbon. The activated carbon is
known to remove toxic organic gases and may provide optimal odor removal.
4.
The fourth stage filtration is a woven fiberglass filtration media used to reduce the amount of
activated carbon fines from migrating out of the filters.

1.2 Inspection

The Bovie
Smoke Shark Surgical Smoke Evacuator was thoroughly tested and inspected prior to
®
shipment. Please inspect the Bovie
items have been received and that no damage occurred during transit. If items are missing or damage is
evident, please contact Customer/Technical Services.

Items Included:

• Operator's Manual
• Filter
• Power Cord
• Automatic Activation Device
• Wall Mounting Kit

1.3 Operational Information

The operational information contained in this section is intended for customer review of technical
specifications. The information pertains to the use of the products both domestically and internationally:
1.
Both the 100/120 VAC, 50/60 Hz and 220/240 VAC, 50/60 Hz Bovie
Evacuators comply with IEC60601-1 electrical specifications.
2.
Type of protection against electrical shock (ANSI/AAMI ES 60601-1, Clause 6.1): Class I
3.
Degree of protection against electric shock (ANSI/AAMI ES 60601-1, Clause 6.2): Type CF Applied Part
4.
Degree of protection against ingress of water (ANSI/AAMI ES 60601-1, Clause 6.3): IPX0
5.
Method of sterilization or disinfection recommended (ANSI/AAMI ES 60601-1, Clause 6.4):
Unplug Bovie
Smoke Shark Surgical Smoke Evacuator. Wipe Bovie
®
Smoke Evacuator with a damp cloth containing mild disinfectant solution or soapy water.
Wipe dry with a clean cloth. Do not steam sterilize.
6.
Degree of safety of application in the presence of flammable anesthetic mixture with air or with
oxygen or nitrous oxide (ANSI/AAMI ES 60601-1, Clause 6.5): Not Suitable
7.
Mode of operation (ANSI/AAMI ES 60601-1, Clause 6.6): Continuous
Customer/Technical Services: 800.251.3000 (United States) or +1 615.964.5532 (International)
DESCRIPTION / INTRODUCTION: SECTION 1.0
Smoke Shark Surgical Smoke Evacuator before using to ensure all
®
Smoke Shark Surgical Smoke
®
Smoke Shark Surgical
®
P000027200 Rev A Bovie
Smoke Shark III Operator's Manual
®
Page 6

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis