Ametek dunkermotoren BG 65S PB Serie Betriebsanleitung Seite 44

Inhaltsverzeichnis

Werbung

Up to 30 parameters can be transmitted to the motor
by the Profibus-parameterization. The first twelve
parameters are parameters which almost always
need to be adjusted. Therefore, every of these
parameters have got an own name. A parameter,
two values can be set: Load to Device?
(No = parameter is not sent to the motor,
Yes = parameter is sent to the motor), as well as the
value which should be written to the parameter.
If an invalid value is entered in the
parameters (e.g. at the address or
value) the motor do not accept the
parameterization. The data exchange
is not proceed. The motor remains in
the state Wait_PRM with the error:
incorrect parameter setting.
Version 05.2017 | Page/ Seite 44
Es können bei der Profibusparametrierung bis zu 30
Parameter an den Motor übergeben
werden. Bei den ersten zwölf Parametern handelt es
sich um Parameter, die fast immer
angepasst werden müssen. Daher sind diese mit Na-
men hinterlegt. Zu einem Parameter
können zwei Werte eingestellt werden: Load to Device?
(No = Parameter wird nicht an den
Motor gesendet, Yes = Parameter wird an den Motor
gesendet), sowie der Wert der auf den
Parameter geschrieben werden soll.
Falls in den Parametern ein unzuläs-
siger Wert eingegeben wird (bei der
Adresse oder dem Wert) akzeptiert der
Motor die Parametrierung nicht und
geht damit auch nicht in den Daten-
austausch. Der Motor bleibt in dem
Zustand Wait_PRM mit dem Fehler:
Fehlerhafte Parametrierung.